2020 官网升级中!现在您访问官网的浏览器设备分辨率宽度低于1280px请使用高分辨率宽度访问。
Catalytic hydrotreating is the treatment of liquid hydrocarbons in a hydrogen environment. This process removes 90% of impurities such as sulfur, nitrogen, oxygen and metals from the feed. Hydrotreating can also be used for hydrodearomatization (HDAr), heavy diesel oil hydrocracking (HDHDC), dewaxing, and improving the performance of pyrolysis gas and diesel.
During the hydrotreating process, the gas/liquid separator and the liquid level of the water wash tank need to be monitored. Liquid level instruments suitable for high temperature and high pressure environments are the key to removing impurities. Because impurities can adversely affect the quality of equipment, catalysts and finished products.
The manufacturing technology of RF2000 series guided wave radar level gauges all come from our company. After years of demonstration by radar liquid level experts, the quality and quality are guaranteed in all aspects; RF2000 series guided wave radar level gauges have various forms and installation methods, which are almost suitable for The measurement of the entire liquid (interface) surface can also be applied to the measurement of dust, flour, sand and granular materials, which can completely replace the use of buoys and magnetic liquid level gauges; it has many advantages, such as during the measurement process, Its measurement accuracy is not affected by changes in medium density, temperature, pressure, etc.; it also has simple installation and debugging methods, and it can be used only by inputting configuration data. It is a relatively advanced liquid level instrument and is widely used in petroleum , chemical industry, electric power, metallurgy, pharmaceutical, food, oil and grain storage and other industries.
● Two-wire DC 24V power supply with low power consumption and HART communication protocol.
● Transmitter head has good compatibility and high stability.
● The performance is not affected by the change of technological conditions such as the specific gravity of the medium, the dielectric constant, and the temperature within the specified range.
● The coaxial antenna (probe) assembly has a unique sealing form, no leakage, high pressure resistance, not easy to aging, and long life.
● The double-rod probe will not affect the correct measurement when part of the material hangs on it, and has high measurement accuracy.
● RF2000 series transmitters can measure medium with extremely low dielectric constant which cannot be measured by traditional guided wave radar.
● RF2000 series transmitters are suitable for medium liquid level measurement under high temperature and high pressure working conditions.
● Rod type probe length can reach 0.5~6m, and cable type can reach 21m.
● Transmitter part (meter head) is interchangeable, and maintenance is more convenient.
● The zero position and range can be adjusted locally, or remotely adjusted through a remote handheld operator, desktop or portable computer.
UHZ-517 series magnetic flap liquid level gauge is a new type of on-site display instrument. The product has the characteristics of simple structure, intuitive and novel reading, no blind spot in observation, large measurement range, safety and reliability, and convenient installation, use and maintenance. This product is widely used in petroleum, chemical industry, electric power, metallurgy, light industry, pharmaceutical, papermaking, environmental protection and other industries to provide on-site indication of the liquid level in various storage tanks, tanks and other containers, and the company’s production All kinds of liquid level transmitters and liquid level switches realize the automatic process control and measurement of various industries.
● Simple structure, intuitive and novel reading, no blind spot in observation, large measurement range, safe and reliable, easy to install, use and maintain.
● The float is made of 304, 316 (L), 321, PP, PVC, PTFE and F46 materials, and the float has good high temperature resistance, which can reach 520°C.
● The welding process meets the requirements of PED welding process. The outer cylinder is made of 304 and 316L materials, and the maximum pressure resistance can reach 25Mpa.
● Optional local indication type, remote transmission type, and liquid level alarm type.
● According to the needs of customers, through various types of production, it can be applied to various working conditions.
The integrated orifice flowmeter uses standard or non-standard throttling devices to generate differential pressure signals, and detects differential pressure and fluid pressure and temperature signals through differential pressure, pressure and temperature sensors, and then through conversion electrical appliances and CPU processing, the influence on the Various factors of measurement accuracy are dynamically fully compensated on-line, and the flow rate of the fluid can be accurately measured, and various media such as liquid, gas, and steam can be measured. Among them, the throttling device implements the standard of GB/T2624-93 “Measurement of Fluid Flow Filled with Round Pipe by Orifice Plate, Nozzle and Venturi Tube for Flow Measurement Throttling Device”.
● LGY700 integrated orifice flowmeter has compact structure, simple installation, and can save a lot of installation work time.
● All products are assembled in the factory to ensure stable and consistent measurement accuracy.
●Imported differential pressure transmitter is adopted, and the throttling device implements the national standard, and the actual measurement accuracy is determined through the inspection of the flow standard device.
● Equipped with temperature and pressure compensation algorithm, which improves the measurement accuracy of actual working conditions.