After desalting, the crude oil enters a distillation column where distillation separates the hydrocarbons into different distillation sections, cut-offs, or fractions. In order to separate mixed liquids, the principle of different volatility (boiling point) of different liquids under different conditions is used for liquid separation, so as to achieve the purification effect.
Level control must cope with foaming, foaming and moderate to high temperatures.
The manufacturing technology of RF2000 series guided wave radar level gauges all come from our company. After years of demonstration by radar liquid level experts, the quality and quality are guaranteed in all aspects; RF2000 series guided wave radar level gauges have various forms and installation methods, which are almost suitable for The measurement of the entire liquid (interface) surface can also be applied to the measurement of dust, flour, sand and granular materials, which can completely replace the use of buoys and magnetic liquid level gauges; it has many advantages, such as during the measurement process, Its measurement accuracy is not affected by changes in medium density, temperature, pressure, etc.; it also has simple installation and debugging methods, and it can be used only by inputting configuration data. It is a relatively advanced liquid level instrument and is widely used in petroleum , chemical industry, electric power, metallurgy, pharmaceutical, food, oil and grain storage and other industries.
● Two-wire DC 24V power supply with low power consumption and HART communication protocol.
● Transmitter head has good compatibility and high stability.
● The performance is not affected by the change of technological conditions such as the specific gravity of the medium, the dielectric constant, and the temperature within the specified range.
● The coaxial antenna (probe) assembly has a unique sealing form, no leakage, high pressure resistance, not easy to aging, and long life.
● The double-rod probe will not affect the correct measurement when part of the material hangs on it, and has high measurement accuracy.
● RF2000 series transmitters can measure medium with extremely low dielectric constant which cannot be measured by traditional guided wave radar.
● RF2000 series transmitters are suitable for medium liquid level measurement under high temperature and high pressure working conditions.
● The length of rod type probe rod can reach 0.5~6m, and the length of cable type probe rod can reach 21m
● The transmitter part (meter head) is interchangeable, and the maintenance is more convenient.
● The zero position and range can be adjusted locally, or remotely adjusted through a remote handheld operator, desktop or portable computer.
UHZ-517 series magnetic flap liquid level gauge is a new type of on-site display instrument. The product has the characteristics of simple structure, intuitive and novel reading, no blind spot in observation, large measurement range, safety and reliability, and convenient installation, use and maintenance. This product is widely used in petroleum, chemical industry, electric power, metallurgy, light industry, pharmaceutical, papermaking, environmental protection and other industries to provide on-site indication of the liquid level in various storage tanks, tanks and other containers, and the company’s production All kinds of liquid level transmitters and liquid level switches realize the automatic process control and measurement of various industries.
● Simple structure, intuitive and novel reading, no blind spot in observation, large measurement range, safe and reliable, easy to install, use and maintain.
● The float is made of 304, 316 (L), 321, PP, PVC, PTFE and F46 materials, and the float has good high temperature resistance, which can reach 520°C.
● The welding process conforms to the requirements of PED welding process. The outer cylinder is made of 304 and 316L materials, and the maximum pressure resistance can reach 25Mpa.
● Optional local indication type, remote transmission type, and liquid level alarm type.
● According to the needs of customers, through various types of production, it can be applied to various working conditions.
LC series displacer type liquid level gauge is designed according to the principle of Archimedes buoyancy, and is used to measure liquid level, interface and density of liquid. It has high measurement stability, especially suitable for liquid level/interface measurement occasions with small range, high temperature, high pressure, and low density, and can meet the interface measurement with small medium density difference. The transmitter can conveniently perform remote configuration and management (monitoring) of the transmitter through the HART communication protocol, using a PC or a general-purpose handheld terminal, and can also be operated with conventional local keys.
● Double SIL 2 certification of France BV and Shanghai SITIIAS.
● Provides 4-20 mA and with HART, 475 Field Communicator for on-site configuration, calibration and diagnostics.
● Comprehensive fault diagnosis, warning and status history.
● PED pressure vessel certification that meets the requirements of the European Union, and the applicable pressure can reach up to 42MPa.
● Can be used in non-steam applications up to a maximum process temperature of 500°C.
● CSA, ATEX and IEC explosion-proof, intrinsically safe certification.
● Process parameters can be adjusted online.
● The meter head of the transmitter can be switched freely in 8 directions without affecting the on-site process.
● Suitable for interface measurement and density detection.
● (EMC) EU Electromagnetic Compatibility Directive CE certification.
LC3020 series electric float level transmitter is an updated product of ordinary electric float level transmitter, which is composed of measurement part and signal controller part. The measurement part can be divided into small corner and large corner according to the structural characteristics. The meter head part of the transmitter is separated from the measuring machine, so that the explosion-proof level is improved, and the full intelligence + HART signal transmission makes the measurement more accurate; LC3020 series electric float level transmitter is directly installed on various storage tank equipment. It is especially suitable for hot heavy oil (temperature ≤ 500°C, pressure ≤ 4.0MPa), viscous and dirty medium, asphalt, oil containing fat, etc. in the refinery, as well as the liquid level of flammable, explosive, corrosive and other media (interface ) continuous measurement, can be widely used in petroleum, chemical industry, metallurgy, medicine and other industrial fields, and is an ideal level instrument in the production process control of petroleum, chemical industry, metallurgy, electric power and light industry and other industries.
● Use integral flange connection, reduce leakage points, reduce leakage possibility, high reliability, and minimal maintenance.
● The structure is simple, the debugging is convenient, and the liquid level gauge can be adjusted without using any special tools.
● Suitable for liquid level measurement of high temperature and high pressure, viscous or impurity-containing media.
LG series orifice flowmeter is a differential pressure generating device for measuring flow. It can be used with various differential pressure gauges or differential pressure transmitters to measure the flow of various fluids in pipelines. It has the advantages of simple structure, convenient installation, stable performance and high accuracy, and can be used for flow measurement of liquid, steam and gas in modern industry. The throttling device of the orifice flowmeter is used in conjunction with the differential pressure transmitter to measure the flow of liquid, steam, and gas. It is widely used in petroleum, chemical, metallurgy, electric power, light industry and other departments.
● The structure is easy to replicate, simple and firm, with stable and reliable performance, long service life and low price.
● Orifice plate calculation adopts international standards and processing.
● The orifice flowmeter has a wide range of applications. It can measure all single-phase flows and some mixed-phase flows.
● The standard throttling device can be put into use without actual flow calibration.
● Imported monocrystalline silicon intelligent differential pressure sensor.
● High precision, complete self-diagnosis function.
● Intelligent orifice flowmeter The measuring range of the intelligent orifice flowmeter can be adjusted by programming.
● Intelligent orifice flowmeter can simultaneously display cumulative flow, instantaneous flow, pressure and temperature.
● In addition to the online and dynamic full compensation function, the intelligent orifice flowmeter also has self-diagnosis and self-setting range.
● Equipped with various communication interfaces.
● High stability.
● Wide measuring range, greater than 10:1.