Open system cooling towers remove waste heat from the steam cycle by exposing the cooling water directly to the atmosphere. After evaporative heat removal, the remaining cooling water flows into the sump. Liquid level control applications include a high level switch to avoid cooling tower sump overflow. In a once-through cooling system, the water intake structure is usually a vertical sump well pump, which requires high and low water level detection and possible pump control.


Challenge:

Feed and sump levels to cooling towers require level detection and control. In cold climates, the level switch can work with electric heaters to protect the standing water in the cooling tower sump from freezing ice.


Products:

● RF2000 Series Guided Wave Radar Level Meter

The manufacturing technology of RF2000 series guided wave radar level gauges all come from our company. After years of demonstration by radar liquid level experts, the quality and quality are guaranteed in all aspects; RF2000 series guided wave radar level gauges have various forms and installation methods, which are almost suitable for The measurement of the entire liquid (interface) surface can also be applied to the measurement of dust, flour, sand and granular materials, which can completely replace the use of buoys and magnetic liquid level gauges; it has many advantages, such as during the measurement process, Its measurement accuracy is not affected by changes in medium density, temperature, pressure, etc.; it also has simple installation and debugging methods, and it can be used only by inputting configuration data. It is a relatively advanced liquid level instrument and is widely used in petroleum , chemical industry, electric power, metallurgy, pharmaceutical, food, oil and grain storage and other industries.

Features:

● Two-wire DC 24V power supply with low power consumption and HART communication protocol.

● The performance will not be affected by the change of process conditions such as the specific gravity, dielectric constant and temperature of the medium within the specified range.

● The coaxial antenna (probe) assembly has a unique sealing form, no leakage, high pressure resistance, not easy to aging, and long life.

● The double-rod probe will not affect the correct measurement when part of the material hangs on it, and has high measurement accuracy.

● It can measure the medium with extremely low dielectric constant which cannot be measured by traditional guided wave radar.

● RF2000 series transmitters are suitable for medium liquid level measurement under high temperature and high pressure working conditions.

● The length of the rod type probe rod can reach 0.5~6m, and the length of the cable type probe rod can reach 21m

● The transmitter part (meter head) is interchangeable, more convenient for maintenance, good compatibility and high stability.

● The zero position and range can be adjusted on site, and can also be adjusted remotely through a remote handheld operator, desktop, or portable computer.


● UQK6 series float (float) liquid level switch

UQK-6000/6100 series float liquid level switch and UQK-6200 series float liquid level switch are designed and manufactured according to high temperature and high pressure applications. The products refer to ANSIB31.1 standard design, adopt advanced three-magnet mechanism switch, reasonable and reliable structure High performance, can accurately identify the liquid level under harsh working conditions, and perform switching actions. It is suitable for the control, alarm and fault interlock of various high-temperature, high-pressure and open container liquid levels in the production process of petroleum, chemical, electric power, food, pharmaceutical and other industries.

When UQK series products are designed and manufactured, they fully consider the different forms of process connection in the imported equipment in the petrochemical industry, and design a variety of installation methods with various structures. It is an ideal substitute for similar switches in Europe and America.

Features:

● Unique “three magnets” mechanism, no spring, no cam, no friction surface.

● Explosion-proof sealed structure, alumina ceramic switch body.

● Suitable for high temperature, high pressure, low temperature, ultra-low temperature, shockproof occasions.

● ANSI B31.1 standard design.

● 316L guide rod, high temperature resistant permanent rare earth magnet.

Bioreactor

A bioreactor is a device system that uses the biological functions of enzymes or organisms (such as microorganisms) to perform biochemical reactions in vitro. It is a biological function simulator, such as a fermenter, immobilized enzyme or immobilized cell reactor wait.

07-12

2022

Filtering System

The sterilizing filter mainly uses a microfiltration filter element with a large specific surface area and a filtration accuracy of 0.22 μm or more. It is mainly used to prevent impurities in the air, harmful bacteria, and microorganisms from interfering, causing changes in water quality, products, and the environment of the sterile room.

07-12

2022

Autoclave

The autoclave has 4 chambers in which the product is sterilized with saturated steam. Sterilization with high temperature and high pressure can kill common bacteria, fungi and other microorganisms, as well as spores and spores. It is the most reliable and widely used physical sterilization method.