Thermal Gas Mass Flow Meter

The ST1 series thermal gas mass flowmeter produced by Shanghai Xingshen Instrument Co., Ltd. is a high-performance product, which is suitable for the fields of industry, environment, energy monitoring and process control, and uses the most advanced sensor technology. This product uses a direct digital control sensor, which is different from the traditional analog circuit used by other thermal flow sensors on the market. It can quickly and accurately respond to changes in process variables, and has the advantage of high precision. Its unique mass flow sensor is composed of two thermal resistance sensors. One is a self-heating sensor for media energy; the other provides a temperature reference. The sensor is programmed to provide a fixed ratio between the two probes instead of the usual constant temperature excitation method. This excitation method essentially eliminates sensor temperature drift while providing precise control of the correspondingly low self-thermal conductivity. Another advantage of the low temperature difference is that it has a higher explosion-proof level, that is, this instrument can be used in a more severe explosion-proof environment.

Features
1. Thermal conduction principle, no moving parts, easy installation and maintenance
2. Advanced and reliable DDC-Sensor™ digital sensor technology
3. Gas-SelectX® gas selection menu function
4. CAL-Check® on-site calibration verification
5. Plug-in models support online installation under pressure
6. Support low-voltage and high-voltage online plugging (with tractor), good shock resistance
7. The pipeline model supports NPT and flange connection of various specifications
8. Different pipe materials are available
9. Explosion-proof certification. CE mark
10.4-20mA flow or HART optional
11. Second output selection: pulse output flow/cumulative value, RS485ModbusRTU, or BACnetMS/TP, FF protocol
12. Free Messaging Software
13. High alarm and low alarm settings
Selection data Contact us
Technical Parameters
  1. Accurate grades: 0.5, 1.0, 1.5, 2.0, 2.5
  2. Velocity range: (0.07~160) m/s
  3. Length of straight pipe section: plug-in type: upstream 15D, downstream 10D; pipeline type: upstream 8D, downstream 4D
  4. Repeatability: ±0.2%FS
  5. Process connection: 3/4NPT ferrule connection; flange connection; online plugging
  6. Response time: 0.8 seconds (time constant)
  7. Velocity range: 15~60, 0~160 m/s
  8. Turndown ratio: 10:1, special up to 100:1
  9. Nominal pressure: PN≤10.0MPa
  10. Working temperature: -40~250℃
  11. Flange standard: HG/T20592, HG/T20615, or user specified
  12. Power supply: DC 24V or AC220V
  13. Power consumption: ≤18W
  14. Output signal: 4~20mA (photoelectric isolation, maximum load 500Ω), pulse
  15. Communication protocol: MODBUS (RS-485), HART protocol
  16. Alarm output: 1-2 relay normally open contacts, 10A/220VAC, 5A/30VDC
  17. Explosion-proof mark: Ex d II C T2~T6 Gb, Ex ia II C T2~T6 Ga
  18. Protection grade: IP65
  19. Power interface: M20×1.5; 1/2NPT