Power supply voltage: 12 ~ 32VDC (standard is 24VDC)
Output signal: two-wire system 4~20mADC, HART communication protocol or FF bus
On-site indicator: Intelligent 5-digit LCD digital display with backlight
Intelligent fault alarm: low point alarm current 3.6mA, high point alarm current 22.8mA
Migration characteristics: After positive and negative migration, the upper and lower limits of the range must not exceed the limit of the range, the maximum positive migration is 500% of the minimum adjustment range, and the maximum negative migration is 600% of the minimum adjustment range
Ambient temperature: Electronic circuit: -40~+85℃
Influence of electromagnetic radiation: The maximum error of the change value is less than 0.05% when the radio frequency electromagnetic radiation level is the highest level 3 V/m, and the scanning frequency range is 100-1000MHz, which meets the IEC801 standard design
Effect of electrostatic discharge: under the highest level of contact discharge level 4 8kV, the maximum change error of the change value is less than 0.05%
Electrical interface: two 1/2NPT, one end is a stainless steel plug, the other end is a standard cable locking joint, interchangeable, for flameproof type, equipped with explosion-proof cable joints, suitable for wiring cables with an outer diameter of φ8~φ10
Protection class: IP66
Explosion-proof mark: Ex db II CT2~T6 Gb, Ex ia II CT2~T4 Ga
Installation method: directly connected to the process or installed on the pipeline through a bracket
Junction box material: low copper die-casting aluminum alloy, surface sprayed with epoxy resin.