2020 官网升级中!现在您访问官网的浏览器设备分辨率宽度低于1280px请使用高分辨率宽度访问。
Measuring range: 300~3000mm
Maximum allowable error: ±0.5%FS, ±1%FS
Power supply voltage: 24VDC (12V~30VDC); the transmitter has reverse polarity protection
Output signal: analog: 4~20mADC, digital: HART1200 baud frequency shift keying (FSK)
Communication protocol: HART, FF field bus
Liquid crystal display LCD: mA or liquid level (interface) mm height, temperature, torque tube angle and percentage range
Load resistance: 600Ω (when powered by 24VDC)
Density: ρ≤2g/cm3
Density difference: ≥0.05g/cm3
Nominal pressure: PN≤42.0MPa
Process temperature: -196~500℃
Ambient temperature: indicating instrument: +5℃~+40℃, sensor: -40℃~+85℃
Insulation interface: G1/2″ external thread, or specified by the user
Explosion-proof mark: Ex iaⅡC T1~T5 Ga, Ex dⅡC T1~T6 Gb
Protection level: NEMA4X and IEC60529 IP66
Electrical interface: 1/2NPT internal thread
Flange standard: ANSI B16.5, HG/T 20592, HG/T 20615, or specified by the user
Material: Inner float: 304SS, 316SS, 316LSS
Holder: 20#, 304SS, 316LSS, 2205, Hastelloy, Monel, etc.
Insulation jacket: 304SS
Outer buoy: 20#, 304SS, 316LSS, 2205, Hastelloy, Monel, etc.
Torque tube: standard configuration is Inconel 600, optional 316L, Hastelloy, etc.
Junction box: aluminum alloy
※ The company can make special design according to the special parameters and requirements of users