2020 官网升级中!现在您访问官网的浏览器设备分辨率宽度低于1280px请使用高分辨率宽度访问。
Measuring range: 0~10m
Maximum allowable error: Class A: ±0.2%FS; Class B: ±0.5%FS
Output signal: 4~20mADC, 4~20mA+HART, digital signal
Communication protocol: HART, or FF field bus
Nominal pressure: PN≤42.0MPa
Process temperature: -196~500℃
Ambient temperature: indicating instrument: +5℃~+40℃, sensor: -40℃~+85℃
Explosion-proof mark: Ex d ia IIC T4/T6 Ga/Gb, Ex d IIC T4/T6 Gb
Protection class: IP66 (NAME 4X)
Electrical interface: 1/2NPT internal thread
Insulation interface: G1/2″ external thread, or specified by the user
Flange standard: ANSI B16.5, HG/T 20592, HG/T 20615, or specified by the user
Wetted material: 20#, 304SS, 316SS, 316LSS, etc.
Power supply voltage: 24VDC
LCD display: mA or liquid level (interface) millimeter height and percentage range
Load resistance: 650Ω (when powered by 24VDC)
Density: ρ≤2g/cm3
Density difference: ≥0.05g/cm3
Effects of working conditions:
Power supply impact: when the voltage changes between the specified minimum and maximum voltages, the output changes ≤±0.2% FS
Temperature influence: ≤0.1%/10℃
Material: Inner float: 304SS, 316SS, 316LSS
Holder: 20#, 304SS, 316LSS, 2205, Hastelloy, Monel, etc.
Insulation jacket: 304SS
Outer buoy: 20#, 304SS, 316LSS, 2205, Hastelloy, Monel, etc.
Torque tube: Inconel 600 is standard, 316LSS, Hastelloy, etc. are optional
Junction box: aluminum alloy, optional stainless steel
※ The company can make special design according to the special parameters and requirements of users