Output signal: two-wire system 4~20mA+HART
Communication protocol: HART , Modbus , FF field bus
Power supply voltage: 24VDC
Explosion-proof mark: Ex ia ⅡC T4~T6 Ga, Ex d ⅡC T4~T6 Gb
Nominal pressure: ≤42MPa
Medium temperature: -50℃≤t≤520℃
Probe length: coaxial, rod type ≤6.1m
Electrical interface: M20×1.5, 1/2NPT, or user specified
Maximum allowable error: ±0.1%FS
Temperature effect: approximately (0.02%) per degree Celsius change in probe length
Data update: 30ms
Load resistance: ≤650Ω
Damping time: 0~32s adjustable
Diagnostic alarm: 3.6mA, 22mA, HOLD (latching)
User interface: 3 buttons + LCD display
Ambient temperature: -40~+80℃
Relative humidity: 0~99%RH
Flange standard: HG/T20592 or user specified
Shell material: aluminum + plastic spraying
Protection class: IP66