2020 官网升级中!现在您访问官网的浏览器设备分辨率宽度低于1280px
请使用高分辨率宽度访问。

SHANGHAI XINGSHEN INSTRUMENT CO.,LTD.

Back to list

Digital display light column indication adjustment alarm instrument

XGTH-510, XGTA-810, and XMTA-810 display control instruments are intelligent display control instruments improved on the basis of the company's original light column indicating digital display adjustment alarm instrument, which integrates digital measurement display and analog measurement display. LEDs accurately display real-time measurement values, while using high-precision 100-line light columns to clearly and intuitively simulate real-time measurement ranges. The instrument uses a microprocessor for mathematical operations, and can be used for measurement and control of various temperatures, pressures, liquid levels, etc. Using jumper-free technology, it is possible to switch and input a variety of graduation numbers. When changing the input graduation number, there is no need to change jumpers or switches. Just set the graduation number and related parameters of the instrument, and the input graduation number can be completed online. Change. Communication interfaces (such as RS-485, etc.) can also be provided according to user requirements to communicate with various devices with input and output to form an intelligent management system.

Features
1. The dedicated integrated instrument chip has more reliable anti-interference and stability.
2. Universal signal input, which can be connected with commonly used thermal signals through menu settings.
3. The display range, transmission output range, alarm value and alarm mode can be modified online.
4. The anti-interference mode combined with software and hardware can effectively suppress the on-site interference signal.
5. Digital calibration technology, no adjustable parts such as potentiometers.
6. The temperature of the cold junction of the thermocouple and the resistance of the thermal resistance lead are automatically compensated.
7. It can provide power distribution function for external two-wire and three-wire transmitters.
8. With photoelectric isolation transmission output function.
9. It has the function of light column analog display.
10. With RS232 or RS485 communication function, it can be connected with the host computer to form a data acquisition system and a control system.
11. Equipped with six relay alarms (the instrument with this function needs to be ordered separately).
Selection data Contact us
Technical Parameters

Input signal: thermocouple: standard thermocouple – B, S, K, .E, J, T, WRe, etc.; resistance: standard thermal resistance – Pt10, Pt100, Cu50, etc., remote pressure resistance 30 ~ 350Ω; current : 0 ~ 10mA (input impedance ≤ 500Ω), 4 ~ 20mA, 0 ~ 20mA (input impedance ≤ 250Ω); voltage: 0 ~ 5V, 1 ~ 5V, etc. (input impedance ≥ 250kΩ), various mV signals (input impedance ≥ 10 MΩ)

Display mode: -1999~9999 measurement and setting value display; 0~100% measurement value bar display; LED working status display

Maximum allowable error: ±0.2%FS±1 byte or ±0.5%FS±1 byte; light bar display error is ±1%FS

Output signal: Analog output: DC0~10mA (load ≤750Ω) or DC 4~20mA (load capacity ≤500Ω), DC0~5V (output capacity ≤250Ω) or DC 1~5V (output capacity ≤250Ω); switching value Output: Relay control output: Relay ON/OFF with return difference; Contact capacity: 240VAC/5A; 24VDC/7A (resistive load); SCR control output: SCR (SCR zero-crossing trigger pulse) output; Trigger thyristor: 400V/100A; Solid state relay output: SSR (solid state relay control signal) output, 6 ~ 24V/30mA; Communication output: Interface method: Standard two-way communication interface: RS-485, RS-232, etc.; Output: 24VDC, load capacity ≤30mA

Control and alarm mode: 1 to 4 limit relay ON/OFF with hysteresis control can be selected, LED indicates alarm status

Temperature compensation: 0 ~ 50 ℃ digital temperature automatic compensation

Parameter setting: Digital setting of light touch buttons on the panel; parameter setting value is permanently saved after power off; parameter setting value is locked by password

Protection mode: input circuit disconnection alarm (when thermocouple or resistance is input), relay output status LED indication; input over/under range alarm; power supply undervoltage automatic reset; abnormal work automatic reset (Watch Dog)

Use environment: Ambient temperature: -10~55℃; Relative humidity≤85RH

Power supply voltage: conventional type: 220VAC 50Hz; special type: 90VAC ~ 260VAC switching power supply; 24VDC switching power supply

Insulation resistance: input/output/power supply/communication≥100MΩ

Power consumption: ≤5W

Structure: standard snap-in

Weight: 420g (220VAC linear power supply.); 260g (switching power supply)

Download
Solution
Related Products
Back to list

XINGSHENCONTACT XINGSHEN

400-160-8800

ADDRESS:NO.8,Xuanzhong Road,Xuanqiao Town, PuDong New Area, Shanghai, China 201399

TEL:+86-021-58308800

FAX:+86-021-58309955

E-mail:foxc@xingshen.com

Scan for more information