2020 官网升级中!现在您访问官网的浏览器设备分辨率宽度低于1280px
请使用高分辨率宽度访问。

SHANGHAI XINGSHEN INSTRUMENT CO.,LTD.

Back to list

Displacer Level Transmitter

LC3015 series displacer liquid level gauge has the characteristics of stable precision, good linearity, and simple installation. It can be read directly on site, and can be transmitted 4~20mA or HART communication. This liquid level gauge can be used to measure liquid level, interface or density. . Use a HART communicator such as the 475 compatible with the LC3015 Series Displacer Level Gauge to obtain information from the process, smart level controller, or displacer measurement chamber. The HART communicator can be connected to the field junction box of the displacer level gauge. It can be directly read on site, and it can also be 4~20mA remote transmission or HART communication

Features
LC3015 series displacer liquid level gauge is designed according to the principle of buoyancy. There is a built-in buoy in the measured medium. When the liquid level changes, the buoyancy on the buoy will also change, so the length of the spring connected to the buoy will change accordingly. The spring will drive the magnetic steel to move, which will change the magnetic field near the Hall sensor. This change is proportional to the buoyancy (the height of the liquid level). The Hall sensor converts the magnetic signal into a DC mV signal. Wire 4~20mA linear DC current signal and load digital signal in accordance with HART protocol communication.
The main structure of LC3015 displacer liquid level gauge is as shown in the figure. It is mainly composed of indicator head (divided into three types: local indication, intrinsically safe type and flameproof type), riser assembly (built-in spring tension mechanism), buoy (length depends on measurement scope) and top nut (can be used for venting and flushing).
Selection data Contact us
Technical Parameters

Power supply voltage: 24VDC

Output signal: 4~20mA or (4~20mA)+HART

On-site indication: pointer indication

Maximum allowable error: ±1.5%FS

Nominal pressure: PN ≤ 42MPa

Medium temperature: t ≤ 500°C

Medium density: ≥0.4g/cm³

Explosion-proof grade: Ex ia II CT2~T4Ga, Ex d II CT2~T6Gb

Electrical interface: M20×1.5, 1/2NPT(F), or specified by the user

Load resistance: ≤650Ω

Ambient temperature: -40~+85℃

Humidity: 0~100%

Flange standard: HG/T20592, HG/T20615, or as specified by the user

Shell material: cast aluminum + plastic spraying

Protection class: IP66